Accessibility settings

Published on in Vol 15 (2026)

Preprints (earlier versions) of this paper are available at https://preprints.jmir.org/preprint/113321, first published .
Healthcare professional adjusting a fitness tracker on a patient's wrist

Authors’ Reply: Accelerometer-Based Step Counts May Be Confounded by Repetitive Motor Behaviors in Adults With Autism Spectrum Disorder

Authors’ Reply: Accelerometer-Based Step Counts May Be Confounded by Repetitive Motor Behaviors in Adults With Autism Spectrum Disorder

1Department of Physical Therapy, Nicole Wertheim College of Nursing & Health Sciences, Florida International University, 11200 SW 8th St, AHC3-424, Miami, FL, United States

2Department of Physical Therapy, Miller School of Medicine, University of Miami, Coral Gables, FL, United States

3Child and Family Services, College of Arts and Sciences, University of Miami, Coral Gables, FL, United States

4Biostatistics, Robert Stempel College of Public Health and Social Work, Florida International University, Miami, FL, United States

5Department of Physical Therapy, College of Health Sciences, University of Delaware, Newark, DE, United States

*these authors contributed equally

Corresponding Author:

Annabel Nunez-Gaunaurd, PT, PhD


JMIR Res Protoc 2026;15:e113321

doi:10.2196/113321

Keywords


We thank the authors of the letter to the editor [1] for their thoughtful comments regarding our protocol paper, “Remote Assessment of Physical Function and Physical Activity in Adults With Autism Spectrum Disorder: Protocol for Feasibility, Validity, and Reliability Study” [2]. We appreciate their interest in the methodological considerations surrounding accelerometer-derived step counts in adults with autism spectrum disorder (ASD).

The authors raise an important concern regarding the potential influence of repetitive motor behaviors, including stereotypic movements such as hand flapping, rocking, and pacing, on accelerometer-based step count estimates. We agree that consumer-grade wearable devices are primarily developed and validated in neurotypical populations and that movement characteristics unique to individuals with ASD may affect measurement accuracy [3,4]. In particular, wrist-worn accelerometers may not consistently distinguish ambulatory activity from certain repetitive movements, potentially leading to overestimation of step counts in some cases. However, the extent to which repetitive motor behaviors influence Fitbit-derived step counts in adults with ASD remains largely unknown. To our knowledge, there is limited evidence regarding the validity of Fitbit-derived step counts in adults with ASD, particularly among individuals who exhibit prominent repetitive motor behaviors. While prior studies have successfully used Fitbit devices to monitor physical activity and evaluate physical activity interventions in adults with ASD, these studies were not designed to establish the criterion validity of step-count measurements in this population [5].

The purpose of our study was to examine the construct validity and test-retest reliability of remotely administered physical function assessments in adults with ASD. Consistent with our analytic framework, Fitbit-derived step counts were included as one of several indicators of physical activity and functioning, alongside measures of lower-extremity function, fall risk, and comorbidity burden, to evaluate the construct validity of patient-reported physical function. Fitbit step counts were not intended to serve as a criterion standard for physical function assessment.

We agree that future studies comparing Fitbit-derived step counts with criterion measures such as direct observation, video-coded step counts, or research-grade accelerometry in adults with ASD would be valuable. Research-grade devices that provide access to raw acceleration signals may allow investigators to better distinguish ambulatory activity from stereotypic movements. However, these measures involve greater cost, analytic complexity, and participant burden. Consumer wearables such as Fitbit devices remain a viable option for large-scale and remote studies because they provide a practical, scalable, and objective estimate of physical activity. Establishing their validity and limitations in adults with ASD is therefore an important area for future research. However, such validation was beyond the scope of the current pilot study and protocol.

We appreciate the authors for highlighting this important issue. Continued research on the validity of wearable activity-monitoring technologies in adults with ASD will help strengthen the interpretation and application of physical activity metrics in both research and clinical practice.

Funding

The authors declared no financial support was received for this work.

Conflicts of Interest

None declared.

  1. Malik MA, Fatima T. Accelerometer-based step counts may be confounded by repetitive motor behaviors in adults with autism spectrum disorder. JMIR Res Protoc. 2026;1:e110988. [CrossRef]
  2. Nunez-Gaunaurd A, Tovin MM, Hale M, Li T, Bhat A. Remote assessment of physical function and physical activity in adults with autism spectrum disorder: protocol for feasibility, validity, and reliability study. JMIR Res Protoc. Aug 31, 2026;15:e86020. [CrossRef] [Medline]
  3. Toth LP, Park S, Springer CM, Feyerabend MD, Steeves JA, Bassett DR. Video-recorded validation of wearable step counters under free-living conditions. Med Sci Sports Exerc. Jun 2018;50(6):1315-1322. [CrossRef] [Medline]
  4. Melo C, Ruano L, Jorge J, et al. Prevalence and determinants of motor stereotypies in autism spectrum disorder: a systematic review and meta-analysis. Autism. Apr 2020;24(3):569-590. [CrossRef] [Medline]
  5. Savage MN, Tomaszewski BT, Hume KA. Step it up: increasing physical activity for adults with autism spectrum disorder and intellectual disability using supported self-management and Fitbit technology. Focus Autism Other Dev Disabl. Sep 2022;37(3):146-157. [CrossRef]


‎
ASD: autism spectrum disorder


Edited by Surya Nedunchezhiyan; This is a non–peer-reviewed article. submitted 30.Sep.2026; accepted 09.Oct.2026; published 30.Oct.2026.

Copyright

© Annabel Nunez-Gaunaurd, Melissa M Tovin, Melissa Hale, Tan Li, Anjana Bhat. Originally published in JMIR Research Protocols (https://www.researchprotocols.org), 30.Oct.2026.

This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Research Protocols, is properly cited. The complete bibliographic information, a link to the original publication on https://www.researchprotocols.org, as well as this copyright and license information must be included.